| Parameter | Requirement delta-R | Test Method |
| Limit | Typical |
| Resistance | Within regulated tolerance | -- | 25°C |
| T.C.R. | Within specified T.C.R. | -- | +25°C/-55°C and +25°C/+125°C |
| Overload | ±1.0% | ±1.0% | Rated power x 5 for 5 seconds |
| Resistance to Solder Heat | ±1.0% | ±1.0% | 260°C ± 5°C, 10 seconds ± 1 second |
| Rapid Change of Temperature | ±1.0% | ±0.5% | -55°C (30 minutes), +125°C (30 minutes), 500 cycles |
| Moisture Resistance | ±2.0% | ±0.5% | 40°C ± 2°C, 90 - 95% RH, 1000 hours, 1.5 hr ON, 0.5 hr OFF cycle |
| Endurance at 70°C | ±1.0% | ±0.5% | 70°C ± 2°C, 1000 hours, 1.5 hr ON, 0.5 hr OFF cycle |
| Low Temperature Operation | ±0.5% | ±0.25% | -55°C, 1 hour |
| High Temperature Exposure | ±0.5% | ±0.25% | +125°C, 100 hours |